You are currently viewing our boards as a guest which gives you limited access to view most discussions and inserts advertising. By joining our free community you will have access to post topics, communicate privately with other members, respond to polls, upload content and access many other special features without post based advertising banners. Registration is simple and absolutely free so please, join our community today!

If you have any problems with the registration process or your account login, please contact us.

Please Note: All new registrations go through a manual approval queue to keep spammers out. This is checked twice each day so there will be a delay before your registration is activated.

Go Back   Australian Ford Forums > Club and Speciality Forums > Forum Community Car Clubs > AU Falcon.com.au

Reply
 
Thread Tools Display Modes
Old 16-09-2012, 12:15 PM   #1
tim_pato
Regular Member
 
tim_pato's Avatar
 
Join Date: Dec 2011
Location: tamworth nsw
Posts: 308
Default pressure test on aircon after seal replacement

My ute had no gas in the aircon when i got it. If i take the seals out of a system that was holding fine and put them in my ute, can i pump the system up with a compressor to see if it holds pressure?

tim_pato is offline   Reply With Quote Multi-Quote with this Post
Old 16-09-2012, 12:34 PM   #2
Herrod Motorsport
www.sctflashtuning.com
 
Herrod Motorsport's Avatar
 
Join Date: Jan 2005
Posts: 3,142
Default Re: pressure test on aircon after seal replacement

You need to hold it in a vacuum not pressure
__________________
Australia's No1 Ford Enhancement Specialist
103 Northgate Drive
Thomastown
VIC 3074

Phone: 03 9464 5100
Fax: 03 9464 5166
Herrod Motorsport is offline   Reply With Quote Multi-Quote with this Post
Old 16-09-2012, 02:20 PM   #3
aussiblue
FG XR6 Ute & Sedan
Donating Member3
 
Join Date: Oct 2006
Location: Bibra Lake WA
Posts: 23,615
Technical Contributor: For members who share their technical expertise. - Issue reason: Has been floating around the oze tech section for a long time and is always there to give advice when people have an issue. 
Default Re: pressure test on air con after seal replacement

Used seals will leak as they conform to the fittings they were used in and will hold that slightly distorted shape. Buy new ones as they are cheap enough. e.g. :

http://www.ebay.com.au/itm/O-ring-ki...item3cca03464e

http://www.ebay.com.au/itm/FJC-4278-...item5d2951258f

You also need to lube the O ring seals with compressor oil before fitting them and torque the fittings to spec.

Compressed air will also add water into the system that you don't want (it very quickly causes corrosion and leaks). For this reason leak testing of an empty system is usually done by filling with oxygen free dry Nitrogen gas. Your best bet is to get whatever shop that is going to refill the system to also do the dry nitrogen gas leak test first. Before the refill vacuum will then be applied for around 30 minutes to remove any air or moisture from the lines not to test for leaks.

In addition to being environmentally friendly and much more visible when it leaks, the smaller nitrogen molecules will detect leaks that air con gas will also escape through but not the larger air and water molecules.
__________________
regards Blue

Last edited by aussiblue; 16-09-2012 at 02:40 PM.
aussiblue is offline   Reply With Quote Multi-Quote with this Post
Old 16-09-2012, 03:15 PM   #4
tim_pato
Regular Member
 
tim_pato's Avatar
 
Join Date: Dec 2011
Location: tamworth nsw
Posts: 308
Default Re: pressure test on aircon after seal replacement

Ok thanks.
tim_pato is offline   Reply With Quote Multi-Quote with this Post
Old 16-09-2012, 07:15 PM   #5
aussiblue
FG XR6 Ute & Sedan
Donating Member3
 
Join Date: Oct 2006
Location: Bibra Lake WA
Posts: 23,615
Technical Contributor: For members who share their technical expertise. - Issue reason: Has been floating around the oze tech section for a long time and is always there to give advice when people have an issue. 
Default Re: pressure test on aircon after seal replacement

Here's another good reason not to use compressed air:

Quote:
DO NOT USE COMPRESSED AIR to test for leaks. Even a system without refrigerant will still contain oil. Oil and compressed air = possible explosion.
http://www.etcs.pwp.blueyonder.co.uk/msg1.htm
__________________
regards Blue